Infrastructure > Experimental Devices > RVS-3

RVS-3

RVS-3


The loop is designed for material and radioactivity transport investigation under PWR/VVER conditions. The RVS-3 loop facility enables the performance of irradiation experiments in a wide range of operational parameters limited by maximum parameters as listed below.

Maximum Parameters

Pressure 16.5 MPa
Temperature 345 °C
Cooling water flow rate 10 000 kg/h
Neutron flux (E > 1 MeV) ~ × 1018
Neutron flux of thermal neutrons (E < 0.025 MeV) ~ × 1018
Power demand 120 kW

Description

The loop is a closed stainless steel system with typical technological auxiliary systems. The experimental equipment of the loop consists of:

  • Active (in-pile) channel situated in the reactor core for irradiation of materials samples
  • Out-of-pile test section providing the same thermal-hydraulic parameters as in-pile channel
  • Electrically heated rods for corrosion tests of fuel cladding materials
  • Loading facility for investigation of corrosion fatigue at low-cycle load and SSRT test
  • Filtration system equipped with mechanical and ion exchange filters
  • Make-up water system for water environment preparation and dosing into the loop system
  • Sampling system (including isokinetic) for water sampling from different points of the loop
  • High-temperature sensors for water chemistry monitoring (conductivity, pHT, ECP)

 

Experimental possibilities

  • Investigation of degradation and corrosion behaviour of structural materials’ mechanical properties under irradiation and PWR/VVER water chemistry and thermal-hydraulic conditions
  • Investigation of behaviour (corrosion, hydriding) of fuel cladding materials under influence of irradiation, thermal flux and water chemistry conditions
  • Investigation of radioactivity transport and behaviour under PWR/VVER conditions (e.g. influence of water chemistry, pHT regime, zinc injection ammonia etc.)
  • Testing of high-temperature, high-pressure sensors for water chemistry monitoring
  • Research of corrosion products transport, influence of water environment, pH, zinc
  • High-temperature monitoring of water regimes testing

RVS-3 Loop Chart

RVS-3 Chart


 

1 main circulation pump;
2 electrical heater;
3 out-of-pile test section;
4 active channel;
5 cooler;
6 pressurizer;
7 filtration circuit